<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	xmlns:georss="http://www.georss.org/georss" xmlns:geo="http://www.w3.org/2003/01/geo/wgs84_pos#" xmlns:media="http://search.yahoo.com/mrss/"
	>

<channel>
	<title>InfraSegura</title>
	<atom:link href="http://infrasecurity.wordpress.com/feed/" rel="self" type="application/rss+xml" />
	<link>http://infrasecurity.wordpress.com</link>
	<description>Crônicas sobre Segurança digital em sistemas de supervisão e controle (SCADA/DCS).</description>
	<lastBuildDate>Wed, 09 Nov 2011 18:15:03 +0000</lastBuildDate>
	<language>pt-br</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
	<generator>http://wordpress.com/</generator>
<cloud domain='infrasecurity.wordpress.com' port='80' path='/?rsscloud=notify' registerProcedure='' protocol='http-post' />
<image>
		<url>http://s2.wp.com/i/buttonw-com.png</url>
		<title>InfraSegura</title>
		<link>http://infrasecurity.wordpress.com</link>
	</image>
	<atom:link rel="search" type="application/opensearchdescription+xml" href="http://infrasecurity.wordpress.com/osd.xml" title="InfraSegura" />
	<atom:link rel='hub' href='http://infrasecurity.wordpress.com/?pushpress=hub'/>
		<item>
		<title>Novo padrão de segurança da informação para a indústria de automação é lançado</title>
		<link>http://infrasecurity.wordpress.com/2010/11/11/novo-padrao-de-seguranca-da-informacao-para-a-industria-de-automacao-e-lancado/</link>
		<comments>http://infrasecurity.wordpress.com/2010/11/11/novo-padrao-de-seguranca-da-informacao-para-a-industria-de-automacao-e-lancado/#comments</comments>
		<pubDate>Thu, 11 Nov 2010 12:27:06 +0000</pubDate>
		<dc:creator>jcfaial</dc:creator>
				<category><![CDATA[Estratégia]]></category>
		<category><![CDATA[Gerenciamento]]></category>
		<category><![CDATA[Normas e Padrões]]></category>
		<category><![CDATA[SCADA]]></category>
		<category><![CDATA[Segurança da Informação]]></category>
		<category><![CDATA[ISA99]]></category>
		<category><![CDATA[Security Standards]]></category>

		<guid isPermaLink="false">http://infrasecurity.wordpress.com/?p=82</guid>
		<description><![CDATA[A &#8220;International Instrument Users&#8217; Association&#8221; (WIB) publicou hoje a segunda versão do &#8220;Process Control Domain &#8212; Security Requirements For Vendors&#8220;, definido como o &#8220;primeiro padrão internacional a descrever uma série de requisitos e melhores práticas de segurança da informação para fornecedores de sistemas de automação e controle&#8221;. O documento é o resultado de uma cooperação [...]<img alt="" border="0" src="http://stats.wordpress.com/b.gif?host=infrasecurity.wordpress.com&amp;blog=1263476&amp;post=82&amp;subd=infrasecurity&amp;ref=&amp;feed=1" width="1" height="1" />]]></description>
		<wfw:commentRss>http://infrasecurity.wordpress.com/2010/11/11/novo-padrao-de-seguranca-da-informacao-para-a-industria-de-automacao-e-lancado/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
	
		<media:content url="" medium="image">
			<media:title type="html">jcfaial</media:title>
		</media:content>
	</item>
		<item>
		<title>Palestra na ISA Brazil Automation 2010 foi bem recebida</title>
		<link>http://infrasecurity.wordpress.com/2010/11/11/palestra-na-isa-brazil-automation-2010-foi-bem-recebida/</link>
		<comments>http://infrasecurity.wordpress.com/2010/11/11/palestra-na-isa-brazil-automation-2010-foi-bem-recebida/#comments</comments>
		<pubDate>Thu, 11 Nov 2010 12:03:53 +0000</pubDate>
		<dc:creator>jcfaial</dc:creator>
				<category><![CDATA[SCADA]]></category>
		<category><![CDATA[Segurança da Informação]]></category>
		<category><![CDATA[Tecnologia]]></category>
		<category><![CDATA[ISA99]]></category>
		<category><![CDATA[Network Security]]></category>
		<category><![CDATA[Stuxnet]]></category>
		<category><![CDATA[vírus]]></category>

		<guid isPermaLink="false">http://infrasecurity.wordpress.com/?p=80</guid>
		<description><![CDATA[Minha palestra na ISA Brazil Automation 2010 foi muito bem recebida. Muito obrigado a todos que estiveram lá e mais uma vez, me desculpem pela velocidade. Muito assunto para falar em pouco tempo&#8230; A feira e congresso ISA Brazil 2010 está sendo realizada no ExpoCenter Norte em São Paulo. Tudo muito bem organizado e com [...]<img alt="" border="0" src="http://stats.wordpress.com/b.gif?host=infrasecurity.wordpress.com&amp;blog=1263476&amp;post=80&amp;subd=infrasecurity&amp;ref=&amp;feed=1" width="1" height="1" />]]></description>
		<wfw:commentRss>http://infrasecurity.wordpress.com/2010/11/11/palestra-na-isa-brazil-automation-2010-foi-bem-recebida/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
	
		<media:content url="" medium="image">
			<media:title type="html">jcfaial</media:title>
		</media:content>
	</item>
		<item>
		<title>Tragédia da DeepWater Horizon teria sido causada por falha em computador.</title>
		<link>http://infrasecurity.wordpress.com/2010/08/23/tragedia-da-deepwater-horizon-teria-sido-causada-por-falha-em-computador/</link>
		<comments>http://infrasecurity.wordpress.com/2010/08/23/tragedia-da-deepwater-horizon-teria-sido-causada-por-falha-em-computador/#comments</comments>
		<pubDate>Mon, 23 Aug 2010 14:13:43 +0000</pubDate>
		<dc:creator>jcfaial</dc:creator>
				<category><![CDATA[Energia]]></category>
		<category><![CDATA[Segurança da Informação]]></category>

		<guid isPermaLink="false">http://infrasecurity.wordpress.com/?p=74</guid>
		<description><![CDATA[Após o testemunho do eletricista  chefe embarcado na DeepWater ao congresso americano, no dia 23 de julho, alguns sites e jornais estão publicando informações que dariam a entender que uma falha no micro onde rodam os sistemas de automação do processo de drilling teria sido a causa do defeito que levou a explosão e consequente [...]<img alt="" border="0" src="http://stats.wordpress.com/b.gif?host=infrasecurity.wordpress.com&amp;blog=1263476&amp;post=74&amp;subd=infrasecurity&amp;ref=&amp;feed=1" width="1" height="1" />]]></description>
		<wfw:commentRss>http://infrasecurity.wordpress.com/2010/08/23/tragedia-da-deepwater-horizon-teria-sido-causada-por-falha-em-computador/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
	
		<media:content url="" medium="image">
			<media:title type="html">jcfaial</media:title>
		</media:content>
	</item>
		<item>
		<title>Microsoft libera patch para corrigir vulnerabilidade dos arquivos LNK/Atalho</title>
		<link>http://infrasecurity.wordpress.com/2010/08/04/microsoft-libera-patch-para-corrigir-vulnerabilidade-dos-arquivos-lnkatalho/</link>
		<comments>http://infrasecurity.wordpress.com/2010/08/04/microsoft-libera-patch-para-corrigir-vulnerabilidade-dos-arquivos-lnkatalho/#comments</comments>
		<pubDate>Wed, 04 Aug 2010 17:49:52 +0000</pubDate>
		<dc:creator>jcfaial</dc:creator>
				<category><![CDATA[SCADA]]></category>

		<guid isPermaLink="false">http://infrasecurity.wordpress.com/?p=71</guid>
		<description><![CDATA[A vulnerabilidade que permitiu a disseminação do vírus Stuxnet, que afeta sistemas SCADA, e agora equipa o portfolio de um sem número de outros malwares, já possui um patch de correção, lançado de forma emergencial pela Microsoft. A empresa, que a alguns anos resolveu concentrar o lançamento de patches em lotes mensais, resolveu lançar a [...]<img alt="" border="0" src="http://stats.wordpress.com/b.gif?host=infrasecurity.wordpress.com&amp;blog=1263476&amp;post=71&amp;subd=infrasecurity&amp;ref=&amp;feed=1" width="1" height="1" />]]></description>
		<wfw:commentRss>http://infrasecurity.wordpress.com/2010/08/04/microsoft-libera-patch-para-corrigir-vulnerabilidade-dos-arquivos-lnkatalho/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
	
		<media:content url="" medium="image">
			<media:title type="html">jcfaial</media:title>
		</media:content>
	</item>
		<item>
		<title>Relatório do DoE: infraestrutura do sistema elétrico americano é vulnerável a cyber ataques.</title>
		<link>http://infrasecurity.wordpress.com/2010/08/04/relatorio-doe-cyber-ataque/</link>
		<comments>http://infrasecurity.wordpress.com/2010/08/04/relatorio-doe-cyber-ataque/#comments</comments>
		<pubDate>Wed, 04 Aug 2010 17:27:24 +0000</pubDate>
		<dc:creator>jcfaial</dc:creator>
				<category><![CDATA[Energia]]></category>
		<category><![CDATA[Redes]]></category>
		<category><![CDATA[SCADA]]></category>
		<category><![CDATA[hmi]]></category>
		<category><![CDATA[ICS]]></category>
		<category><![CDATA[scada]]></category>
		<category><![CDATA[vulnerabilidades]]></category>

		<guid isPermaLink="false">http://infrasecurity.wordpress.com/?p=69</guid>
		<description><![CDATA[O DoE (Department of Energy) americano, equivalente do nosso Ministério de Minas e Energia, publicou um excelente relatório sobre o resultado de diversos testes de segurança conduzidos na infraestrutura de energia elétrica (grid) deles. Os testes foram conduzidos pelo Laboratório Nacional de Idaho no perído de 2003 a 2009 e compreendeu 24 ICSs (Industrial Control [...]<img alt="" border="0" src="http://stats.wordpress.com/b.gif?host=infrasecurity.wordpress.com&amp;blog=1263476&amp;post=69&amp;subd=infrasecurity&amp;ref=&amp;feed=1" width="1" height="1" />]]></description>
		<wfw:commentRss>http://infrasecurity.wordpress.com/2010/08/04/relatorio-doe-cyber-ataque/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
	
		<media:content url="" medium="image">
			<media:title type="html">jcfaial</media:title>
		</media:content>
	</item>
		<item>
		<title>Siemens libera patch para o Simatic WinCC e PCS 7</title>
		<link>http://infrasecurity.wordpress.com/2010/07/23/siemens-libera-patch-para-o-simatic-wincc-e-pcs-7/</link>
		<comments>http://infrasecurity.wordpress.com/2010/07/23/siemens-libera-patch-para-o-simatic-wincc-e-pcs-7/#comments</comments>
		<pubDate>Fri, 23 Jul 2010 13:12:27 +0000</pubDate>
		<dc:creator>jcfaial</dc:creator>
				<category><![CDATA[SCADA]]></category>
		<category><![CDATA[Stuxnet]]></category>

		<guid isPermaLink="false">http://infrasecurity.wordpress.com/?p=56</guid>
		<description><![CDATA[A Simens liberou um update para o sistema Simatic WinCC, alvo escolhido pelo primeiro vírus escrito para invadir redes SCADA (veja os posts anteriores).  Pela documentação que acompanha o update, parece que por hora, trata-se de uma solução ainda paliativa e provisória. Extraído das instruções do update: &#8220;This Security Update supports you in protecting your [...]<img alt="" border="0" src="http://stats.wordpress.com/b.gif?host=infrasecurity.wordpress.com&amp;blog=1263476&amp;post=56&amp;subd=infrasecurity&amp;ref=&amp;feed=1" width="1" height="1" />]]></description>
		<wfw:commentRss>http://infrasecurity.wordpress.com/2010/07/23/siemens-libera-patch-para-o-simatic-wincc-e-pcs-7/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
	
		<media:content url="" medium="image">
			<media:title type="html">jcfaial</media:title>
		</media:content>
	</item>
		<item>
		<title>Uma alternativa ao antívirus?</title>
		<link>http://infrasecurity.wordpress.com/2010/07/22/uma-alternativa-ao-antivirus/</link>
		<comments>http://infrasecurity.wordpress.com/2010/07/22/uma-alternativa-ao-antivirus/#comments</comments>
		<pubDate>Thu, 22 Jul 2010 14:05:19 +0000</pubDate>
		<dc:creator>jcfaial</dc:creator>
				<category><![CDATA[SCADA]]></category>

		<guid isPermaLink="false">http://infrasecurity.wordpress.com/?p=63</guid>
		<description><![CDATA[Acredito que qualquer um com o mínimo de conhecimento sobre redes ou sistemas de controle industrial irá concordar que soluções de segurança que se utilizam de &#8220;agentes&#8221; de host não são uma boa idéia para máquinas encarregadas de processos de supervisão ou controle. O exemplo mais comum de solução de segurança que utiliza o conceito [...]<img alt="" border="0" src="http://stats.wordpress.com/b.gif?host=infrasecurity.wordpress.com&amp;blog=1263476&amp;post=63&amp;subd=infrasecurity&amp;ref=&amp;feed=1" width="1" height="1" />]]></description>
		<wfw:commentRss>http://infrasecurity.wordpress.com/2010/07/22/uma-alternativa-ao-antivirus/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
	
		<media:content url="" medium="image">
			<media:title type="html">jcfaial</media:title>
		</media:content>
	</item>
		<item>
		<title>Mais fatos sobre o vírus Stuxnet</title>
		<link>http://infrasecurity.wordpress.com/2010/07/22/mais-fatos-sobre-o-virus-stuxnet/</link>
		<comments>http://infrasecurity.wordpress.com/2010/07/22/mais-fatos-sobre-o-virus-stuxnet/#comments</comments>
		<pubDate>Thu, 22 Jul 2010 13:03:48 +0000</pubDate>
		<dc:creator>jcfaial</dc:creator>
				<category><![CDATA[SCADA]]></category>

		<guid isPermaLink="false">http://infrasecurity.wordpress.com/?p=60</guid>
		<description><![CDATA[O primeiro vírus especificamente escrito para invadir sistemas SCADA, mas precisamente os sistemas Simatic WinCC e PCS 7, ambos da Siemens, demonstra uma grande e raramente encontrada habilidade no seu desenvolvimento. Coisa de profissional do mais alto nível técnico (não ético ou legal claro). Alguns fatos: O vírus usa um exploit até então desconhecido. Em [...]<img alt="" border="0" src="http://stats.wordpress.com/b.gif?host=infrasecurity.wordpress.com&amp;blog=1263476&amp;post=60&amp;subd=infrasecurity&amp;ref=&amp;feed=1" width="1" height="1" />]]></description>
		<wfw:commentRss>http://infrasecurity.wordpress.com/2010/07/22/mais-fatos-sobre-o-virus-stuxnet/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
	
		<media:content url="" medium="image">
			<media:title type="html">jcfaial</media:title>
		</media:content>
	</item>
		<item>
		<title>Novo vírus usa vulnerabilidade do Windows para atacar redes SCADA</title>
		<link>http://infrasecurity.wordpress.com/2010/07/22/novo-virus-usa-vulnerabilidade-do-windows-para-atacar-redes-scada/</link>
		<comments>http://infrasecurity.wordpress.com/2010/07/22/novo-virus-usa-vulnerabilidade-do-windows-para-atacar-redes-scada/#comments</comments>
		<pubDate>Thu, 22 Jul 2010 12:18:49 +0000</pubDate>
		<dc:creator>jcfaial</dc:creator>
				<category><![CDATA[SCADA]]></category>
		<category><![CDATA[scada]]></category>
		<category><![CDATA[vírus]]></category>

		<guid isPermaLink="false">http://infrasecurity.wordpress.com/?p=58</guid>
		<description><![CDATA[E então a profecia se realiza! O que era apenas uma suposição, bastante provável é verdade, se concretizou: o primeiro vírus especificamente escrito para atacar um sistema SCADA está fazendo vítimas por aí. O vírus, chamado Stuxnet, recentemente descoberto por uma empresa de segurança Russa, explora uma falha grave do Windows &#8220;Vulnerability in Windows Shell [...]<img alt="" border="0" src="http://stats.wordpress.com/b.gif?host=infrasecurity.wordpress.com&amp;blog=1263476&amp;post=58&amp;subd=infrasecurity&amp;ref=&amp;feed=1" width="1" height="1" />]]></description>
		<wfw:commentRss>http://infrasecurity.wordpress.com/2010/07/22/novo-virus-usa-vulnerabilidade-do-windows-para-atacar-redes-scada/feed/</wfw:commentRss>
		<slash:comments>6</slash:comments>
	
		<media:content url="" medium="image">
			<media:title type="html">jcfaial</media:title>
		</media:content>
	</item>
		<item>
		<title>MS08-030: Vulnerabilidade afeta o stack Bluetooth do Windows XP e Vista</title>
		<link>http://infrasecurity.wordpress.com/2008/06/20/ms08-030-vulnerabilidade-afeta-o-stack-bluetooth-do-windows-xp-e-vista/</link>
		<comments>http://infrasecurity.wordpress.com/2008/06/20/ms08-030-vulnerabilidade-afeta-o-stack-bluetooth-do-windows-xp-e-vista/#comments</comments>
		<pubDate>Fri, 20 Jun 2008 14:30:08 +0000</pubDate>
		<dc:creator>jcfaial</dc:creator>
				<category><![CDATA[Redes]]></category>
		<category><![CDATA[Segurança da Informação]]></category>
		<category><![CDATA[Tecnologia]]></category>

		<guid isPermaLink="false">http://infrasecurity.wordpress.com/?p=49</guid>
		<description><![CDATA[Quem usa dispositivos equipados com a tecnologia de comunicação wireless baseada no protocolo Bluetooth, em plataformas Windows, deve ficar atento para uma importante vulnerabilidade recém divulgada pela Microsoft. A falha, permite que dispositivos rodando Windows XP ou Vista equipados com interface bluetooth executem código malicioso remotamente. Quem aplicou o patch original, deve observar que foi [...]<img alt="" border="0" src="http://stats.wordpress.com/b.gif?host=infrasecurity.wordpress.com&amp;blog=1263476&amp;post=49&amp;subd=infrasecurity&amp;ref=&amp;feed=1" width="1" height="1" />]]></description>
		<wfw:commentRss>http://infrasecurity.wordpress.com/2008/06/20/ms08-030-vulnerabilidade-afeta-o-stack-bluetooth-do-windows-xp-e-vista/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
	
		<media:content url="" medium="image">
			<media:title type="html">jcfaial</media:title>
		</media:content>
	</item>
	</channel>
</rss>
